美(mei)國(guo)電(dian)機保(bao)護(hu)SEL電(dian)器710系(xi)列(lie)功(gong)能(neng)全(quan)解
繼(ji)電(dian)器(英(ying)文(wen)名(ming)稱:relay)是壹(yi)種電(dian)控制(zhi)器件,是當(dāng)(dang)輸(shu)入量(激勵量)的變(bian)化達到規(guī)定要求(qiu)時,在(zai)電(dian)氣(qi)輸(shu)出電(dian)路(lu)中(zhong)使被(bei)控量(liang)發(fā)(fa)生(sheng)預(yù)(yu)定的階躍變(bian)化的壹(yi)種電(dian)器。它具有(you)控制(zhi)系統(tǒng)(又(you)稱輸(shu)入回(hui)路(lu))和被控制(zhi)系統(tǒng)(又(you)稱輸(shu)出回(hui)路(lu))之(zhi)間的互(hu)動(dong)關(guān)系(xi)。通(tong)常(chang)應(yīng)(ying)用於(yu)自(zi)動(dong)化的控制(zhi)電(dian)路(lu)中(zhong),它實(shi)際(ji)上(shang)是用(yong)小(xiao)電(dian)流去控制(zhi)大電(dian)流運(yun)作的壹(yi)種“自(zi)動(dong)開關(guān)"。故在(zai)電(dian)路(lu)中(zhong)起(qi)著自(zi)動(dong)調(diào)節(jié)(jie)、安(an)全保(bao)護、轉(zhuǎn)換電(dian)路(lu)等(deng)作用(yong)。
SEL通(tong)過構(gòu)建壹(yi)個基(ji)於(yu)微(wei)處理(li)器(qi)的保護繼(ji)電(dian)器*改變(bian)了電(dian)力系(xi)統(tǒng)保(bao)護(hu)。如(ru)今(jin),SEL在(zai)保(bao)護(hu)繼(ji)電(dian)器中(zhong)具有(you)高(gao)速(su),安全和可靠的故障檢測功(gong)能(neng);準(zhǔn)確的故障定位;以及(ji)全(quan)面的自(zi)動(dong)化和控制(zhi)功(gong)能(neng)。SEL繼(ji)電(dian)器具(ju)有(you)市(shi)場上長的平均(jun)故障間隔時間(MTBF)(超(chao)過500年)。
SEL-710電(dian)動機(ji)保(bao)護(hu)SEL繼(ji)電(dian)器具(ju)有(you)業(yè)(ye)界(jie)很(hen)確切的電(dian)動機(ji)保(bao)護(hu)功(gong)能(neng),以及(ji)易於(yu)使用(yong)的設(shè)置,安裝(zhuang)和通訊選(xuan)項。帶有AccuTrack熱模型的SEL-710確定了長的安全啟動時間(無(wu)需(xu)速度開關(guān)),並(bing)將(jiang)電(dian)動機(ji)啟動之(zhi)間的等(deng)待(dai)時間縮(suo)短(duan)了(le)33%。從七(qi)個通(tong)信(xin)協(xié)議中(zhong)進(jin)行(xing)選(xuan)擇,包括(kuo)以太(tai)網(wǎng)(wang),Modbus和IEC 61850,以快(kuai)速(su)集成(cheng)到控制(zhi)系統(tǒng)中(zhong)。
增(zeng)強(qiang)的電(dian)動機(ji)保(bao)護(hu)功(gong)能(neng)-通(tong)過增(zeng)強(qiang)的熱模型保護(hu)低(di)壓(ya)或中(zhong)壓三(san)相(xiang)電(dian)動機(ji),該(gai)模(mo)型包括(kuo)鎖定的轉(zhuǎn)子(zi)啟動,啟動時間間隔,每(mei)小(xiao)時啟動,防(fang)後(hou)轉(zhuǎn)計時器(qi),負載損失(shi),電(dian)流不平衡(heng),負載阻塞(sai)/轉(zhuǎn)子(zi)失(shi)速,斷(duan)路(lu)器/接(jie)觸器故障,頻率(lv)和過電(dian)流因(yin)素,包括(kuo)相位,負序(xu),接(jie)地(di)瞬(shun)時瞬(shun)時值和反(fan)時限因(yin)素。實(shi)現(xiàn)(xian)負載控制(zhi),星三(san)角(jiao)啟動,正向(xiang)/反(fan)向(xiang)啟動控制(zhi)和兩速控制(zhi)。將(jiang)SEL-710與(yu)可(ke)選(xuan)的電(dian)壓和差(cha)分(fen)電(dian)流輸(shu)入配合(he)使用(yong),可包括(kuo)轉(zhuǎn)子(zi)滑(hua)差(cha)計算,差(cha)分(fen)過電(dian)流(87M),欠壓(ya),過壓,欠功(gong)率(lv),無(wu)功(gong)功(gong)率(lv),相(xiang)變(bian),功(gong)率(lv)因(yin)數(shù)和電(dian)位損失(shi)保護(hu)。
基(ji)於(yu)RTD和PTC的熱保護-將(jiang)多達十個電(dian)阻溫(wen)度(du)檢(jian)測器(RTD)直(zhi)接(jie)連(lian)接(jie)到繼(ji)電(dian)器的可選(xuan)RTD輸(shu)入卡,以監(jiān)(jian)視定子(zi)繞(rao)組(zu),軸(zhou)承(cheng),環(huán)境或其他(ta)電(dian)動機(ji)的工(gong)作溫(wen)度(du)。通過使用(yong)外部(bu)SEL-2600 RTD模(mo)塊收集多達12種*的工(gong)作溫(wen)度(du),並(bing)通(tong)過通信(xin)鏈路(lu)將(jiang)這(zhe)些(xie)溫(wen)度(du)發(fā)(fa)送(song)回(hui)繼(ji)電(dian)器,從(cong)而(er)為(wei)其他(ta)繼(ji)電(dian)器選(xuan)件釋(shi)放(fang)空間。RTD警(jing)報(bao)和跳閘(zha)閾(yu)值提供了靈活(huo)的後(hou)備(bei)保護,還(hai)可以用(yong)於(yu)偏(pian)置(zhi)熱模型或形成(cheng)表決(jue)方(fang)案(an)以確認緩(huan)解決(jue)策。當(dāng)(dang)熱敏電(dian)阻用(yong)作熱備(bei)份測量設(shè)備(bei)時,選(xuan)擇可(ke)選(xuan)的正溫度系(xi)數(shù)(shu)(PTC)熱敏電(dian)阻超(chao)溫輸(shu)入。
惡(e)劣(lie)環(huán)境中(zhong)的可靠保護(hu)— SEL-710在(zai)條(tiao)件下(xia)運(yun)行,工(gong)作溫(wen)度(du)為–40°至+ 85°C(–40°至+ 185°F),並(bing)且(qie)經(jīng)(jing)過設(shè)計和測試,超(chao)出了適(shi)用標(biāo)(biao)準(zhǔn),包括(kuo)振(zhen)動,電(dian)磁兼容(rong)性和不利的環(huán)境條(tiao)件。此(ci)外(wai),SEL-710還(hai)通過了ATEX和Underwriters Laboratories(UL)I類(lei)2級(ji)認證(zheng),可用於(yu)危(wei)險和潛(qian)在(zai)爆(bao)炸(zha)性環(huán)境。
過電(dian)流保護(hu)—通(tong)過反(fan)時限和瞬(shun)時過電(dian)流元(yuan)件為(wei)電(dian)動機(ji)饋(kui)線(xian)提(ti)供備(bei)用過電(dian)流保護(hu)。SEL-710提(ti)供(gong)了(le)完(wan)整的過電(dian)流保護(hu),包括(kuo)相,負序(xu),剩余(yu)和中(zhong)性點(dian)過電(dian)流元(yuan)件。
SEL繼(ji)電(dian)器計(ji)量(liang)和監(jiān)(jian)控—計(ji)量的量包括(kuo)相電(dian)壓和電(dian)流。排序(xu)電(dian)壓和電(dian)流;功(gong)率(lv),頻(pin)率和能(neng)量(liang);以及(ji)選(xuan)定數(shù)量(liang)的大/小記(ji)錄。繼(ji)電(dian)器在(zai)非易失(shi)性存(cun)儲(chu)器(qi)中(zhong)存(cun)儲(chu)多達19個很(hen)新(xin)的64周(zhou)期事(shi)件報(bao)告(gao)或77個很(hen)新(xin)的15周(zhou)期事(shi)件報(bao)告(gao)。當(dāng)(dang)測量條(tiao)件超(chao)出允(yun)許的閾(yu)值時,繼(ji)電(dian)器還(hai)會(hui)監(jiān)(jian)視並(bing)發(fā)(fa)出警(jing)報(bao)。例(li)如(ru),斷(duan)路(lu)器每(mei)次(ci)操作都(dou)會(hui)遭受機械(xie)和電(dian)氣(qi)磨(mo)損。每(mei)次(ci)斷(duan)路(lu)器操作時,繼(ji)電(dian)器都(dou)會(hui)對測量的電(dian)流進(jin)行(xing)積分(fen),並(bing)增(zeng)加斷(duan)路(lu)器操作計(ji)數(shù)(shu)器。當(dāng)(dang)積分(fen)結(jié)(jie)果超(chao)過斷(duan)路(lu)器的磨損曲線(xian)閾(yu)值時,繼(ji)電(dian)器將(jiang)通過輸(shu)出觸點(dian),通訊(xun)端口(kou)或前(qian)面板(ban)顯(xian)示屏(ping)發(fā)(fa)出警(jing)報(bao)。
集成(cheng)和自(zi)動(dong)化-從多達9種通信(xin)協(xié)議中(zhong)進(jin)行(xing)選(xuan)擇,多達4個獨立(li)操作的串行端口(kou),銅纜(lan)或光纖(xian)以太(tai)網(wǎng)(wang)端口(kou)(單(dan)或雙),強(qiang)大的中(zhong)繼(ji)邏(luo)輯(ji)以及(ji)可(ke)編(bian)程的前(qian)面板(ban)選(xuan)項,可將(jiang)SEL-710集成(cheng)到高保(bao)護,自(zi)動(dong)化和控制(zhi)的高性能(neng)系(xi)統(tǒng)。
優(yōu)化啟動時間
SEL-710計(ji)算電(dian)動機(ji)中(zhong)的熱能(neng),以確定大的安全啟動時間,並(bing)具(ju)有(you)完(wan)整的電(dian)動機(ji)保(bao)護(hu)功(gong)能(neng)。很(hen)確切的溫度跟蹤(zong)還(hai)可以很(hen)大程度(du)地減(jian)少啟動之(zhi)間的時間。
方(fang)便的控制(zhi)
使用(yong)前(qian)面板(ban)上(shang)的四個(ge)可(ke)編(bian)程按(an)鈕(niu)進(jin)行(xing)快(kuai)速(su)個性化控制(zhi),並(bing)具(ju)有(you)出廠默認的啟動和停止功(gong)能(neng)。
優(yōu)良的保護
SEL-710為過電(dian)流,熱過載,欠電(dian)流,電(dian)流不平衡(heng),電(dian)流差(cha),相位損耗,接(jie)地(di)故障以及(ji)過高或欠頻等(deng)提(ti)供(gong)保(bao)護。
輕松(song)通(tong)信(xin)
從單或雙,銅纜(lan)或光纖(xian)以太(tai)網(wǎng)(wang)以及(ji)Modbus TCP,IEC 61850,Modbus串(chuan)行,EIA-232,EIA-485,Telnet和文件傳(chuan)輸(shu)協(xié)議(FTP)通信(xin)中(zhong)進(jin)行(xing)選(xuan)擇。選(xuan)擇壹(yi)個或多個連接(jie),包括(kuo)用於(yu)您的應(yīng)用程序(xu)自(zi)定義配(pei)置(zhi)的多個Modbus會(hui)話。
堅固的設(shè)計
值得信(xin)賴(lai),是業(yè)(ye)界(jie)寬(kuan)的環(huán)境工(gong)作溫(wen)度(du)範(fàn)圍,–40°至+ 85°C(–40°至+ 185°F)。SEL-710承(cheng)受振(zhen)動,電(dian)湧,快(kuai)速(su)瞬(shun)變(bian)和溫度,符(fu)合(he)嚴(yán)(yan)格的行業(yè)標(biāo)(biao)準(zhǔn)。印(yin)刷電(dian)路(lu)板(ban)的保形塗層(ceng)選(xuan)項為空氣(qi)中(zhong)的汙染物(例(li)如(ru)硫(liu)化氫,氯,鹽(yan)和濕(shi)氣(qi))提(ti)供了額外的屏障。此外(wai),SEL-710還(hai)通過了ATEX和Underwriters Laboratories(UL)I類(lei)2級(ji)認證(zheng),可用於(yu)危(wei)險和潛(qian)在(zai)爆(bao)炸(zha)性環(huán)境。